03 / Heat Exchangers

Heat exchangers to TEMA & ASME.

Configurations03
Lean Solvent Chiller — tubesheet view, ID 1900mm
Condenser — Alon Vapor Israel Project, ASME U stamp
Overview · 01

Shell-and-tube exchangers, hairpin double-pipe, and air-cooled exchangers — engineered, fabricated, and tube-bundled under one workshop.

Datasheet · 03Rev. 01 · 2026
Code
ASME VIII + TEMA R / C / B
Type
Shell-Tube, Double-Pipe, Air-Cooled
Surface area
up to 2,500 m² per shell
Tube count
up to 3,000 per bundle
Joints
Expanded + strength welded
Materials
CS, SS304/316/321, Duplex, Inconel, Titanium
Configurations · 02

What we build.

Reboilers

Kettle and thermosiphon reboilers for distillation service.

Condensers

Overhead and surface condensers, vertical or horizontal.

Feed / Effluent Exchangers

Process-to-process heat recovery duty.

Coolers

Trim coolers using cooling water or tempered media.

Steam Generators

Waste-heat boilers and steam generators tied to process.

Air-Cooled (Fin-fan)

Forced and induced-draft air-cooled exchangers with finned tube bundles.

Materials & welding · 03

Tube + tubesheet combinations

  • CS / CS — utility duty
  • SS304 / SS304 — clean process
  • SS316L / SS316L — chloride-bearing service
  • Duplex / Duplex — high-chloride, high-stress
  • Ti / Ti — seawater and aggressive halide service
  • CS shell + SS bundle for mixed-service economics

Tube-to-tubesheet

  • Expanded + strength welded per ASME VIII Appendix A
  • GTAW orbital welding for clean root passes
  • Tube bundle assembly in dedicated bay
  • Bundle pull-out clearance designed in from day one
Testing & documentation · 04

Witnessed. Documented.

01

Pull tests

Tube-to-tubesheet pull-out tests per ASME VIII.

02

Helium leak

Mass-spectrometer leak testing for critical and cryogenic service.

03

Pneumatic

Pneumatic shell-side and tube-side tests where hydrotest is impractical.

04

Hydrostatic

Witnessed hydrostatic testing per code and TEMA.

Selected references · 05

Recent deliveries.

All projects
Inquiry · 06

Specifying a heat exchanger? Start here.

Submissions routed directly to the senior engineering desk. Typical response under 24 hours.

Or download the datasheet template
Form · RFQ-03Rev. 01 · 2026